Chemical Synthesis and Characterisation Lab
Instrument
In Situ IR Probes
ReactIR™ Mid-infrared attenuated total reflectance (ATR) technology offers numerous advantages over alternative analytical methods. Researchers and scientists improve chemical development today by leveraging these advantages, including:
CEM Corporation Discoverer SP (Microwave Synthesizer)
Microwave synthesizer is a premier microwave reactor for performing any organic or inorganic synthetic chemistry. Featuring a best-in-class 10 mL single-mode microwave cavity, 15-150 mL open vessel reactor, and intuitive software with a 10" touchscreen interface, it is possible to program a reaction in seconds and achieve the best synthetic yield in minutes.
Features :
• Widest pressurized vessel sizes for a single-mode microwave – 10 mL
• Open vessel reaction mode – 15-150 mL
• IR Temperature Sensor that sees through glass and Teflon® (iWave®)
• Vent and reseal technology for safe handling of over-pressurization (ActiVent)
• Variable speed magnetic stirring and rapid compressed air cooling
• Upgrade options: Autosamplers - 12/48 positions; Gaseous Addition, Sub-ambient temperature, Flow cells
N.B: After the experiment always cool down the reaction vessel and open inside the Fume Hood.
Specifications of Microwave Synthesizer :1.Heating rate2 – 6 °C/second2.Temperature30 – 300 °C Volume-independent infrared (IR) temperature measurement-80 – 300 °C Fiber optic (FO) temperature measurement3.Pressure0 – 30 bar (0 – 435 psi)ActiVent™ technology for safe and automated vessel vent and reseal4.Reflux reactionsAccepts 5 – 125 mL size round bottom flask5.Operating volume0.2 – 25 mL (standard pressurized)5 – 50 mL (80-mL pressurized)0.2 – 75 mL (atmospheric)6.Power0 – 300 W7.Magnetron frequency2450 MHz8.Reaction agitationElectromagnetic stirring with adjustable speeds (Teflon® coated stir bars are suitable)9.Air Cooling≥25 psi (20 L/min flow)User-supplied for simultaneous cooling (PowerMAX™) and post-reaction quenching10.System controlSynergy™ software and/or on-board key pad11.AccessoriesExplorer Automation (unattended operation)Gas Addition Kit (work with gaseous reagents)Cool Mate (sub-ambient chemistry)Fiber Optic (in situ temperature measurement)80-mL scale-up vessel (15 - 50 mL working volume)Flow Cells (continuous flow chemistry)SPPS (solid phas peptide synthesis)Proteomics (parallel enzymatic digestion)12Weight38 lbs (17.3kg)13Dimensions14.2"W x 16.9"D x 11.2" H (36.1 cm x 42.9 cm x 28.4 cm)
300 W Xenon Arc Lamp Source
Samples
No information
Charges
|
||||||||||||||||||||
|
Contact Us
Chemical Synthesis and Characterisation Lab
Instrument
In Situ IR Probes
ReactIR™ Mid-infrared attenuated total reflectance (ATR) technology offers numerous advantages over alternative analytical methods. Researchers and scientists improve chemical development today by leveraging these advantages, including:
CEM Corporation Discoverer SP (Microwave Synthesizer)
Microwave synthesizer is a premier microwave reactor for performing any organic or inorganic synthetic chemistry. Featuring a best-in-class 10 mL single-mode microwave cavity, 15-150 mL open vessel reactor, and intuitive software with a 10" touchscreen interface, it is possible to program a reaction in seconds and achieve the best synthetic yield in minutes.
Features :
• Widest pressurized vessel sizes for a single-mode microwave – 10 mL
• Open vessel reaction mode – 15-150 mL
• IR Temperature Sensor that sees through glass and Teflon® (iWave®)
• Vent and reseal technology for safe handling of over-pressurization (ActiVent)
• Variable speed magnetic stirring and rapid compressed air cooling
• Upgrade options: Autosamplers - 12/48 positions; Gaseous Addition, Sub-ambient temperature, Flow cells
N.B: After the experiment always cool down the reaction vessel and open inside the Fume Hood.
Specifications of Microwave Synthesizer :1.Heating rate2 – 6 °C/second2.Temperature30 – 300 °C Volume-independent infrared (IR) temperature measurement-80 – 300 °C Fiber optic (FO) temperature measurement3.Pressure0 – 30 bar (0 – 435 psi)ActiVent™ technology for safe and automated vessel vent and reseal4.Reflux reactionsAccepts 5 – 125 mL size round bottom flask5.Operating volume0.2 – 25 mL (standard pressurized)5 – 50 mL (80-mL pressurized)0.2 – 75 mL (atmospheric)6.Power0 – 300 W7.Magnetron frequency2450 MHz8.Reaction agitationElectromagnetic stirring with adjustable speeds (Teflon® coated stir bars are suitable)9.Air Cooling≥25 psi (20 L/min flow)User-supplied for simultaneous cooling (PowerMAX™) and post-reaction quenching10.System controlSynergy™ software and/or on-board key pad11.AccessoriesExplorer Automation (unattended operation)Gas Addition Kit (work with gaseous reagents)Cool Mate (sub-ambient chemistry)Fiber Optic (in situ temperature measurement)80-mL scale-up vessel (15 - 50 mL working volume)Flow Cells (continuous flow chemistry)SPPS (solid phas peptide synthesis)Proteomics (parallel enzymatic digestion)12Weight38 lbs (17.3kg)13Dimensions14.2"W x 16.9"D x 11.2" H (36.1 cm x 42.9 cm x 28.4 cm)
300 W Xenon Arc Lamp Source
Samples
No information
Charges
|
||||||||||||||||||||
|
Contact Us
1. Registration process (One Time): New Registration for external users.User Verification: Upload photo of Front side and back side of valid Identity card issued by the organization (only .jpeg format, file Size less than 1 Mb, height less than 1000 pixels, width less than 800 pixels). Undertaking: Download the undertaking template ( Download Link ). Duly filled, signed and stamped form should be uploaded in .pdf format. Confirmation: An email will be sent to the user after verification of the documents.
2.Before planning to avail the Instrument facility of CRF IIT Delhi: user must visit https://crf.iitd.ac.in -> Facility -> select the desired facility from left side navigation list. Read carefully all the relevant information such as required sample type, testing charges and instrument location. Be prepared with details of the samples.
3.Log in and Click on Booking Appointment Tab: All the information relevant to testing must be filled in instrument booking form. In case user does not provide the required information the booking is liable to be rejected. User can upload the relevant existing data of their samples that might help in the measurements.
4.Sample submission & Payment Process: Once the application is submitted, the in-charge will verify the details and approve the request.External users must wait for the approval before making the payment and submitting the samples to concerned lab. After approval the payment should be made by the user. The payment transaction details need to be submitted online before appointment date time.
5.CRF Users can pay amount online using following details:
Beneficiary/Customer's Name: IRD ACCOUNT IITD
Bank Account Number: 10773572600
Bank Name: State Bank of India Branch Name: IIT Branch
Branch Code: 01077
NEFT IFSC CODE / RTGS: SBIN0001077
please write "CRF _Instrument Name" in the Remarks section while paying. Save the receipt file and upload in the crfbooking system online against your application.Payment can also made in form of demand draft in favour of " IRD ACCOUNT IITD " Payable at New Delhi.6.IIT Delhi
GST Number : 07AAATI0393L1ZI
PAN Number : AAATI0393L
1 Registration process (One Time): New Registration for internal users.
Fill in all the details in Personal Information, Supervisor Information and User Login Credentionals.
Once submitted, an email to supervisor is sent for activation of account. Once activated by supervisor, you can do the instrument bookings.
2 Before planning to avail the Instrument facility of CRF IIT Delhi: user must visit https://crf.iitd.ac.in > Facilities > select the desired facility from left side navigation list. Read ca refully all the relevant information such as required sample type, testing charges and instrument location. Be prepared with details of the samples.
3. Log in on CRF Booking System and Click on Booking Appointment Tab: All the information relevant to testing must be filled in instrument booking form. In case user does not provide the required information the booking is liable to be rejected. User can upload the relevant existing data of their samples that might help in the measurements.
4 Sample submission & Payment Process: Once the application is submitted, the in-charge will verify the details and approve the request.