Instrument

  • There are following Table top instruments / tools available under CRF Synthesis Lab.
  • List of Instruments / Tools :Sr.No.Instrument Name
    1. In Situ IR Probes ReactIR™
    2. CEM Corporation Discoverer SP (Microwave Synthesizer)
    3. 300 W Xenon arc lamp source
    4. Glove box (Qty 2)

In Situ IR Probes

ReactIR™ Mid-infrared attenuated total reflectance (ATR) technology offers numerous advantages over alternative analytical methods. Researchers and scientists improve chemical development today by leveraging these advantages, including:

  • Immersible probes for direct insertion into reaction vessel for in situ, continuous, real-time reaction measurements
  • No extractive sampling required, providing the ability to measure chemistry in its natural environment
  • Impervious to bubbles or solids, making it ideal for hydrogenations or any heterogeneous reactions
  • Suitable for aqueous chemistry (optimized path-length to suppress overlap of strong water absorptions vs measurement of key reaction components)
  • Non-destructive technique, preserving the integrity of the chemical reaction
  • Adheres to Beer-Lambert law, enabling both qualitative and quantitative measurements


  • What we Can Do with this In Situ IR Probes
  • Probes designed to operate from low to high temperature, low to high pressure, under acidic, basic, caustic, oxidizing and aqueous conditions enable the analysis of virtually any type of chemistry.
  • Pressure: Vacuum to 69bar
  • Temperature: -80 oC to 180 oC
  • pH: 1 to 14
  • N.B: Do not use concentrated acid and solid samples.
  • ReactIR is optimized for use in the fingerprint region – giving a system with the best sensitivity in the region with the best molecular information
  • ReactIR can be used to prove what happens in the plant is what you observed in the lab
  • Specifically designed to take time resolved spectra and convert them into reaction profiles, iC IR™ answers the key questions – when does it start, when does it stop, do I have an intermediate, what are the kinetics?

CEM Corporation Discoverer SP (Microwave Synthesizer)


Microwave synthesizer is a premier microwave reactor for performing any organic or inorganic synthetic chemistry. Featuring a best-in-class 10 mL single-mode microwave cavity, 15-150 mL open vessel reactor, and intuitive software with a 10" touchscreen interface, it is possible to program a reaction in seconds and achieve the best synthetic yield in minutes.

Features :

• Widest pressurized vessel sizes for a single-mode microwave – 10 mL
• Open vessel reaction mode – 15-150 mL
• IR Temperature Sensor that sees through glass and Teflon® (iWave®)
• Vent and reseal technology for safe handling of over-pressurization (ActiVent)
• Variable speed magnetic stirring and rapid compressed air cooling
• Upgrade options: Autosamplers - 12/48 positions; Gaseous Addition, Sub-ambient temperature, Flow cells
N.B: After the experiment always cool down the reaction vessel and open inside the Fume Hood.

Specifications of Microwave Synthesizer :1.Heating rate2 – 6 °C/second2.Temperature30 – 300 °C Volume-independent infrared (IR) temperature measurement-80 – 300 °C Fiber optic (FO) temperature measurement3.Pressure0 – 30 bar (0 – 435 psi)ActiVent™ technology for safe and automated vessel vent and reseal4.Reflux reactionsAccepts 5 – 125 mL size round bottom flask5.Operating volume0.2 – 25 mL (standard pressurized)5 – 50 mL (80-mL pressurized)0.2 – 75 mL (atmospheric)6.Power0 – 300 W7.Magnetron frequency2450 MHz8.Reaction agitationElectromagnetic stirring with adjustable speeds (Teflon® coated stir bars are suitable)9.Air Cooling≥25 psi (20 L/min flow)User-supplied for simultaneous cooling (PowerMAX™) and post-reaction quenching10.System controlSynergy™ software and/or on-board key pad11.AccessoriesExplorer Automation (unattended operation)Gas Addition Kit (work with gaseous reagents)Cool Mate (sub-ambient chemistry)Fiber Optic (in situ temperature measurement)80-mL scale-up vessel (15 - 50 mL working volume)Flow Cells (continuous flow chemistry)SPPS (solid phas peptide synthesis)Proteomics (parallel enzymatic digestion)12Weight38 lbs (17.3kg)13Dimensions14.2"W x 16.9"D x 11.2" H (36.1 cm x 42.9 cm x 28.4 cm)


300 W Xenon Arc Lamp Source


  • 300 W Xenon lamp is a plug-and-play type bench-top light source that provides a high intensity illumination. The Xenon arc lamp mounted inside the lamp housing can transmit a light with a wavelength from 250-2200 nm region. The equipment can also be used as a visible-light illuminator by choosing the 420 nm cut-off filter which will block the UV light. This lamp is useful for any kind of photochemical conversion, provided that the sample must have a light-harvesting component or a photosensitizer tagged in it. Nanostructured materials with ca. 1.8-3.2 eV band gap can be a suitable photosensitizer and may be chosen for different important reactions like photochemical water splitting, CO2 reduction and/or organic transformations. Any kind of light-mediated physical and chemical transformation can be performed by using this light source.

    Specification of the equipment:
    1. Highly stabilized 300 Watt Ozone free Xe arc lamp source
    2. Light Orientation – Horizontal
    3. Preferably a solution (homogeneous) and/or dispersion (heterogeneous) of a material can be placed near the lamp (approx. 10-15 cm) to illuminate.
    4. The lamp and the sample holder would be placed in a dark cabinet to avoid the interference of external light source of the lab.
    5. Illumination time to be set according to the requirement.


Samples

No information

Charges

Slot Duration Equipment Internal Users Academic & Research Institutions / IITs/IISERs/Univ. Industry
1.5 hr with a cap of max 2 samples GC-MS Rs 100 /- Per sample Rs 400 /- sample (max 1.5 hr) +18% GST 1000 /- sample (max 1.5 hr) +18% GST
10:00 AM- 5:00 PM Synthesis Lab
( Fume Hood assisted with Magnetic stator, Glove box, Microwave synthesiser , Rotary evorator, Weighing balance, Laboratory Oven )

Rs 100 /- Per day Rs 250+18% GST Per day Rs 1000+18% GST per day
10:00 AM- 5:00 PM Characterisation lab (In Situ IR Probes , Nano particle tracking analyser -NTA, xenon arc lamp - 300 Watt ) Rs 100 /- Per day Rs 250+18% GST Per Day Rs 1000+18% GST per day


  • NON IITD User can pay amount online using following details after approval of operational incharge of instrument:
    Beneficiary/Customer's Name: IRD ACCOUNT IITD
    Bank Account Number: 10773572600
    Bank Name: State Bank of India
    Branch Name: IIT Branch
    Branch Code: 01077
    NEFT IFSC CODE / RTGS: SBIN0001077
    Please write "CRF GC-MS CRF IITD" in the Remarks section while paying. Save the receipt file and send it to us at crf.info.iitd@gmail.com along with online CRF application ID Number for payment invoice.
  • Payment can also made in form of demand draft in favour of " IRD ACCOUNT IITD " Payable at New Delhi.


Contact Us

Mailing Address for Samples & Lab Location -
Block 5 Central Reseach Facility (CRF) CRF Synthesis Lab Indian Institute of Technology Hauz Khas, New Delhi-110016, India
Coordinator
Prof. Chinmoy K. Hazra 
Coordinator of GC-MS 
Email: chinmoy@chemistry.iitd.ac.in
Tel.: +91 11 2654-8408 (O)
Operational Incharge 
Dr.Bhupender Singh 
Principal Technical Officer (Incharge) 
Tel.: +91-11-2654 8484 (O) 
Email: bsinghiitd@admin.iitd.ac.in

Operator

Mr. Manoj Kumar Jaiswal
Project Scientist IIT Delhi, Hauz Khas, New Delhi-110016 
Email : ird12415@bioschool.iitd.ac.in

Chemical Synthesis and Characterisation Lab 

Instrument

  • There are following Table top instruments / tools available under CRF Synthesis Lab.
  • List of Instruments / Tools :Sr.No.Instrument Name
    1. In Situ IR Probes ReactIR™
    2. CEM Corporation Discoverer SP (Microwave Synthesizer)
    3. 300 W Xenon arc lamp source
    4. Glove box (Qty 2)

In Situ IR Probes

ReactIR™ Mid-infrared attenuated total reflectance (ATR) technology offers numerous advantages over alternative analytical methods. Researchers and scientists improve chemical development today by leveraging these advantages, including:

  • Immersible probes for direct insertion into reaction vessel for in situ, continuous, real-time reaction measurements
  • No extractive sampling required, providing the ability to measure chemistry in its natural environment
  • Impervious to bubbles or solids, making it ideal for hydrogenations or any heterogeneous reactions
  • Suitable for aqueous chemistry (optimized path-length to suppress overlap of strong water absorptions vs measurement of key reaction components)
  • Non-destructive technique, preserving the integrity of the chemical reaction
  • Adheres to Beer-Lambert law, enabling both qualitative and quantitative measurements


  • What we Can Do with this In Situ IR Probes
  • Probes designed to operate from low to high temperature, low to high pressure, under acidic, basic, caustic, oxidizing and aqueous conditions enable the analysis of virtually any type of chemistry.
  • Pressure: Vacuum to 69bar
  • Temperature: -80 oC to 180 oC
  • pH: 1 to 14
  • N.B: Do not use concentrated acid and solid samples.
  • ReactIR is optimized for use in the fingerprint region – giving a system with the best sensitivity in the region with the best molecular information
  • ReactIR can be used to prove what happens in the plant is what you observed in the lab
  • Specifically designed to take time resolved spectra and convert them into reaction profiles, iC IR™ answers the key questions – when does it start, when does it stop, do I have an intermediate, what are the kinetics?

CEM Corporation Discoverer SP (Microwave Synthesizer)


Microwave synthesizer is a premier microwave reactor for performing any organic or inorganic synthetic chemistry. Featuring a best-in-class 10 mL single-mode microwave cavity, 15-150 mL open vessel reactor, and intuitive software with a 10" touchscreen interface, it is possible to program a reaction in seconds and achieve the best synthetic yield in minutes.

Features :

• Widest pressurized vessel sizes for a single-mode microwave – 10 mL
• Open vessel reaction mode – 15-150 mL
• IR Temperature Sensor that sees through glass and Teflon® (iWave®)
• Vent and reseal technology for safe handling of over-pressurization (ActiVent)
• Variable speed magnetic stirring and rapid compressed air cooling
• Upgrade options: Autosamplers - 12/48 positions; Gaseous Addition, Sub-ambient temperature, Flow cells
N.B: After the experiment always cool down the reaction vessel and open inside the Fume Hood.

Specifications of Microwave Synthesizer :1.Heating rate2 – 6 °C/second2.Temperature30 – 300 °C Volume-independent infrared (IR) temperature measurement-80 – 300 °C Fiber optic (FO) temperature measurement3.Pressure0 – 30 bar (0 – 435 psi)ActiVent™ technology for safe and automated vessel vent and reseal4.Reflux reactionsAccepts 5 – 125 mL size round bottom flask5.Operating volume0.2 – 25 mL (standard pressurized)5 – 50 mL (80-mL pressurized)0.2 – 75 mL (atmospheric)6.Power0 – 300 W7.Magnetron frequency2450 MHz8.Reaction agitationElectromagnetic stirring with adjustable speeds (Teflon® coated stir bars are suitable)9.Air Cooling≥25 psi (20 L/min flow)User-supplied for simultaneous cooling (PowerMAX™) and post-reaction quenching10.System controlSynergy™ software and/or on-board key pad11.AccessoriesExplorer Automation (unattended operation)Gas Addition Kit (work with gaseous reagents)Cool Mate (sub-ambient chemistry)Fiber Optic (in situ temperature measurement)80-mL scale-up vessel (15 - 50 mL working volume)Flow Cells (continuous flow chemistry)SPPS (solid phas peptide synthesis)Proteomics (parallel enzymatic digestion)12Weight38 lbs (17.3kg)13Dimensions14.2"W x 16.9"D x 11.2" H (36.1 cm x 42.9 cm x 28.4 cm)


300 W Xenon Arc Lamp Source


  • 300 W Xenon lamp is a plug-and-play type bench-top light source that provides a high intensity illumination. The Xenon arc lamp mounted inside the lamp housing can transmit a light with a wavelength from 250-2200 nm region. The equipment can also be used as a visible-light illuminator by choosing the 420 nm cut-off filter which will block the UV light. This lamp is useful for any kind of photochemical conversion, provided that the sample must have a light-harvesting component or a photosensitizer tagged in it. Nanostructured materials with ca. 1.8-3.2 eV band gap can be a suitable photosensitizer and may be chosen for different important reactions like photochemical water splitting, CO2 reduction and/or organic transformations. Any kind of light-mediated physical and chemical transformation can be performed by using this light source.

    Specification of the equipment:
    1. Highly stabilized 300 Watt Ozone free Xe arc lamp source
    2. Light Orientation – Horizontal
    3. Preferably a solution (homogeneous) and/or dispersion (heterogeneous) of a material can be placed near the lamp (approx. 10-15 cm) to illuminate.
    4. The lamp and the sample holder would be placed in a dark cabinet to avoid the interference of external light source of the lab.
    5. Illumination time to be set according to the requirement.


Samples

No information

Charges

Slot Duration Equipment Internal Users Academic & Research Institutions / IITs/IISERs/Univ. Industry
1.5 hr with a cap of max 2 samples GC-MS Rs 100 /- Per sample Rs 400 /- sample (max 1.5 hr) +18% GST 1000 /- sample (max 1.5 hr) +18% GST
10:00 AM- 5:00 PM Synthesis Lab
( Fume Hood assisted with Magnetic stator, Glove box, Microwave synthesiser , Rotary evorator, Weighing balance, Laboratory Oven )

Rs 100 /- Per day Rs 250+18% GST Per day Rs 1000+18% GST per day
10:00 AM- 5:00 PM Characterisation lab (In Situ IR Probes , Nano particle tracking analyser -NTA, xenon arc lamp - 300 Watt ) Rs 100 /- Per day Rs 250+18% GST Per Day Rs 1000+18% GST per day


  • NON IITD User can pay amount online using following details after approval of operational incharge of instrument:
    Beneficiary/Customer's Name: IRD ACCOUNT IITD
    Bank Account Number: 10773572600
    Bank Name: State Bank of India
    Branch Name: IIT Branch
    Branch Code: 01077
    NEFT IFSC CODE / RTGS: SBIN0001077
    Please write "CRF GC-MS CRF IITD" in the Remarks section while paying. Save the receipt file and send it to us at crf.info.iitd@gmail.com along with online CRF application ID Number for payment invoice.
  • Payment can also made in form of demand draft in favour of " IRD ACCOUNT IITD " Payable at New Delhi.


Contact Us

Mailing Address for Samples & Lab Location -
Block 5 Central Reseach Facility (CRF) CRF Synthesis Lab Indian Institute of Technology Hauz Khas, New Delhi-110016, India
Coordinator
Prof. Chinmoy K. Hazra 
Coordinator of GC-MS 
Email: chinmoy@chemistry.iitd.ac.in
Tel.: +91 11 2654-8408 (O)
Operational Incharge 
Dr.Bhupender Singh 
Principal Technical Officer (Incharge) 
Tel.: +91-11-2654 8484 (O) 
Email: bsinghiitd@admin.iitd.ac.in

Operator

Mr. Manoj Kumar Jaiswal
Project Scientist IIT Delhi, Hauz Khas, New Delhi-110016 
Email : ird12415@bioschool.iitd.ac.in

Get CRF Registration for 
External users 

1. Registration process (One Time): New Registration for external users.User Verification: Upload photo of Front side and back side of valid Identity card issued by the organization (only .jpeg format, file Size less than 1 Mb, height less than 1000 pixels, width less than 800 pixels). Undertaking: Download the undertaking template ( Download Link ). Duly filled, signed and stamped form should be uploaded in .pdf format. Confirmation: An email will be sent to the user after verification of the documents.

2.Before planning to avail the Instrument facility of CRF IIT Delhi: user must visit https://crf.iitd.ac.in -> Facility -> select the desired facility from left side navigation list.  Read carefully all the relevant information such as required sample type, testing charges and instrument location. Be prepared with details of the samples.

3.Log in and Click on Booking Appointment Tab: All the information relevant to testing must be filled in instrument booking form. In case user does not provide the required information the booking is liable to be rejected. User can upload the relevant existing data of their samples that might help in the measurements.

4.Sample submission & Payment Process: Once the application is submitted, the in-charge will verify the details and approve the request.External users must wait for the approval before making the payment and submitting the samples to concerned lab. After approval the payment should be made by the user. The payment transaction details need to be submitted online before appointment date time.

5.CRF Users can pay amount online using following details:
Beneficiary/Customer's Name: IRD ACCOUNT IITD
Bank Account Number:  10773572600  
Bank Name: State Bank of India Branch Name: IIT Branch
Branch Code: 01077
NEFT IFSC CODE / RTGS: SBIN0001077
please write "CRF _Instrument Name" in the Remarks section while paying. Save the receipt file and upload in the crfbooking system online against your application.Payment can also made in form of demand draft in favour of " IRD ACCOUNT IITD " Payable at New Delhi.6.IIT Delhi 
GST Number : 07AAATI0393L1ZI
PAN Number : AAATI0393L

Signup (External user)

CRF IIT Delhi 
new user registration

IIT Delhi Internal User

.

External User Registration