Small Angle X-ray Scattering (SAXS) (CRF Sonipat Campus)

Small Angle X-ray Scattering (SAXS) is a non-destructive scattering technique by which electron density differences in a sample containing nanoscaled structures can be quantified by recording the scattered X-rays at very low angles (typically 0.1 - 10°). The method can be used to determine nanoparticle (1-100 nm) size distributions, shape, pore sizes, particle density, inter particle distance of partially ordered materials, surface to volume ratio and much more. This is achieved by analysing the elastic scattering behaviour of X-rays when travelling through the material at a very small angle, hence the "Small-angle" in its name.

The materials can be solid or liquid and they can contain solid, liquid or gaseous domains of the same or another material in any combination. Not only particles, but also the structure of ordered systems likes protein, lamellae, and fractal-like materials can be studied. The method is accurate, non-destructive and usually requires only a few amount of sample.

SAXS Make : Anton Paar Model : SAXS point 2.0
SAXS Specification: 
  1. X-ray source :  Primux 100 micro microfocus Cu X-ray source
  2. X-ray optics and collimation : Fully evacuated scatterless beam collimation
  3. Sample-detector distance : Max. 1075 mm
  4. Temperature range : -150 °C to 600 °C 
  5. Sample stages: Temperature-Controlled (TC) stages, GISAXS stage, Tensile Stage, Humidity Stage, Multisampler Stage, ASX autosampler for up to 192 liquid samples.
  6. Detectors : 2D EIGER R series Hybrid Photon Counting (HPC) detectors with HR WAXS module
  7. Accessible q-range: 0.02 nm⁻¹ to 40.7 nm⁻¹
Sample holders with SAXS
  1. Quartz capillary (1 mm) for liquids
  2. Low-parasitics SiN cell
  3. Sample holder for solids
  4. PasteCell for viscous and powder samples
  5. RotorCell for solid sample with spinning
  6. μ-Cell for very small amount of liquid sample
  7. FlowCell for automation
Special Features :
  1. TrueFocus: self-alignment with X-ray beam
  2. TrueSWAXS: simultaneous SWAXS studies up to 60° 2Ѳ3)
  3. StageMaster: YZ stage with auto-recognition of sample stages
  4. Movable detector option
  5. Changeable Beam Stopper
  6. High-resolution WAXS module option
Recommended Samples type:
  1. Solid, Liquid, Gel, Powder, Thin film, Fibre, Polymers, Proteins in nano scale range.
  2. Thin film area: Max. 1.5cm×1.5cm for Square or 1cm Dia for circular shape.
  3. Thin film coating thickness: Max. 50nm; Substrate thickness: Max. 0.5 mm
  4. Liquid Sample quality: Monodisperse macromolecule sample with concentration of 5-20 mg/ml and volume minimum 1 ml for a single measurement. For protein samples, the concentration depends on the size.
  5. Separate Buffer must bring during measurement.
Testing Charges (Click here)

How to contact

Lab-Physical Location: 

SAXS Lab Room No. 07, 
Central Research Facilities (CRF), IIT Delhi Sonipat Campus Rajiv Gandhi Education City,
Rai Industrial Area Rai, 
Sonipat – 131029 Haryana
Landmark : Near Ashoka University

Lab Coordinator

Prof. Bhanu Nandan
Department of Textile and Fibre Engineering
IIT Delhi
Email: nandan@textile.iitd.ac.in
Tel: (91)-11-2659-6679

Operational In-charge

Dr. M. Mehedi Hassan
Principal Project Scientist
Email: ​ird600475@crf.iitd.ac.in

Get CRF Registration for 
External users 

1. Registration process (One Time): New Registration for external users.User Verification: Upload photo of Front side and back side of valid Identity card issued by the organization (only .jpeg format, file Size less than 1 Mb, height less than 1000 pixels, width less than 800 pixels). Undertaking: Download the undertaking template ( Download Link ). Duly filled, signed and stamped form should be uploaded in .pdf format. Confirmation: An email will be sent to the user after verification of the documents.

2.Before planning to avail the Instrument facility of CRF IIT Delhi: user must visit https://crf.iitd.ac.in -> Facility -> select the desired facility from left side navigation list.  Read carefully all the relevant information such as required sample type, testing charges and instrument location. Be prepared with details of the samples.

3.Log in and Click on Booking Appointment Tab: All the information relevant to testing must be filled in instrument booking form. In case user does not provide the required information the booking is liable to be rejected. User can upload the relevant existing data of their samples that might help in the measurements.

4.Sample submission & Payment Process: Once the application is submitted, the in-charge will verify the details and approve the request.External users must wait for the approval before making the payment and submitting the samples to concerned lab. After approval the payment should be made by the user. The payment transaction details need to be submitted online before appointment date time.

5.CRF Users can pay amount online using following details:
Beneficiary/Customer's Name: IRD ACCOUNT IITD
Bank Account Number:  10773572600  
Bank Name: State Bank of India Branch Name: IIT Branch
Branch Code: 01077
NEFT IFSC CODE / RTGS: SBIN0001077
please write "CRF _Instrument Name" in the Remarks section while paying. Save the receipt file and upload in the crfbooking system online against your application.Payment can also made in form of demand draft in favour of " IRD ACCOUNT IITD " Payable at New Delhi.6.IIT Delhi 
GST Number : 07AAATI0393L1ZI
PAN Number : AAATI0393L

Signup (External user)

CRF IIT Delhi 
new user registration

IIT Delhi Internal User

.

External User Registration