Multi-Functional Tribotester (CRF Owned Facility)

Tribotester is an instrument that measures friction, wear, coefficient of friction i.e. tribological properties between two surfaces in contact. Our multi-functional Tribotester has interchangeable modules and load cells, that allows it to run several tests on same platform. Further, it has in-built White Light Interferometer (WLI) that helps create 3D topograpghy of the surface, measure wear volume loss, surface roughness etc.

Instrument Make: Rtec Instruments,USA Model : Multi-Functional Tribotester
Multi-Functional Tribotester is equipped with following modes :
1. Friction and wear
2. Scratch Tester and Indentation
3. Tribo-corrosion
1. Friction and Wear

(a). Rotary mode : 
Speed – 0.5 to 5000 RPM
Load – Upto 5000N
Conditions – Dry & Liquid
Sample size for liquid samples- Upto 50 mm

(b). Linear/Reciprocatory mode Wear
Linear, Continuous & Butterfly types of motion
Load- Upto 5000N
Travel- 150mm x 250mm with a resolution of 10 microns.
Stroke- 1mm to 30mm.
Frequency- Upto 40 Hz

For butterfly type motion, simultaneous force sensing about 3 Axis (30 mN to 2kN) and torque sensing about 3 Axis (0.1 Nm to 20 Nm) can be performed.

2. Scratch Tester and Indentation

(a). Scratch Hardness Tests 
with load upto 200N.
Coating Adhesion Tests.
Scratch Resistance Tests.
Diamond tip radius- 20 µm and 100 µm.

(b) Indentation-
The hardness of a material is defined as a measurement of its resistance to permanent deformation when subjected to a constant compressive load.

(b-i) Micro Indentation:
Load range: 30mN to 60N Rockwell and Vicker Indentor

(b-ii) Macro Indentation
Load range: Upto 5000N
Rockwell and Vicker Indentor

3. Tribo-corrosion:

Tribocorrosion is a degradation process of materials during tribological testing which occurs due to the combined effect of corrosion and wear. Wear and friction tests can be performed in-situ during corrosion

Note: All the Tribology and Indentation Modules have in-situ imaging to estimate material loss, wear rates and roughness with the limited range of magnifications. This can be discussed with the operator. 
Samples requirment for Multi-Functional Tribotester

(1).Rotary mode Sample requirement:
50 mm center screw in sample
Tapping drill size 4 mm
Thikness : 3.50 mm
Click here to view detail description of Rotary mode sample preparation
(Download Link)

(2). Linear/Reciprocatory mode
Minimum Sample Size 20mm x 20mm (l,b)
Maximum Sample Size: 60mm x 50mm (l,b)
Height : (1 to 10mm) preferable

Note: The sample needs to be flat for Scratch and Indentation mode . Feasibility of samples shall be discussed with operator before booking of appointment 
Click here to Get 
CRF Charge List

How to Contact

Physical Location:

Room No. 021
Academic Complex East, 99C
IIT Delhi Hauz Khas New Delhi 110016

Coordinator:

Prof Dinesh Kalyanasundaram
Indian Institute of Technology Delhi Hauz Khas,
New Delhi-110016
Tel:+91-11-2659 7344 (O)
Email : dineshk@cbme.iitd.ac.in

Operational Incharge

Mr. Arun G,
PhD (​2022CTZ8630) 
Email : ​ctz228630@cart.iitd.ac.in 
Phone. ​9809155022

Get CRF Registration for 
External users 

1. Registration process (One Time): New Registration for external users.User Verification: Upload photo of Front side and back side of valid Identity card issued by the organization (only .jpeg format, file Size less than 1 Mb, height less than 1000 pixels, width less than 800 pixels). Undertaking: Download the undertaking template ( Download Link ). Duly filled, signed and stamped form should be uploaded in .pdf format. Confirmation: An email will be sent to the user after verification of the documents.

2.Before planning to avail the Instrument facility of CRF IIT Delhi: user must visit https://crf.iitd.ac.in -> Facility -> select the desired facility from left side navigation list.  Read carefully all the relevant information such as required sample type, testing charges and instrument location. Be prepared with details of the samples.

3.Log in and Click on Booking Appointment Tab: All the information relevant to testing must be filled in instrument booking form. In case user does not provide the required information the booking is liable to be rejected. User can upload the relevant existing data of their samples that might help in the measurements.

4.Sample submission & Payment Process: Once the application is submitted, the in-charge will verify the details and approve the request.External users must wait for the approval before making the payment and submitting the samples to concerned lab. After approval the payment should be made by the user. The payment transaction details need to be submitted online before appointment date time.

5.CRF Users can pay amount online using following details:
Beneficiary/Customer's Name: IRD ACCOUNT IITD
Bank Account Number:  10773572600  
Bank Name: State Bank of India Branch Name: IIT Branch
Branch Code: 01077
NEFT IFSC CODE / RTGS: SBIN0001077
please write "CRF _Instrument Name" in the Remarks section while paying. Save the receipt file and upload in the crfbooking system online against your application.Payment can also made in form of demand draft in favour of " IRD ACCOUNT IITD " Payable at New Delhi.6.IIT Delhi 
GST Number : 07AAATI0393L1ZI
PAN Number : AAATI0393L

Signup (External user)

CRF IIT Delhi 
new user registration

IIT Delhi Internal User

.

External User Registration